24
packets per monitoring cycle. Specify 0 when you want a report as soon as the error is detected.
When the network cable is pulled out or HUB power switch is off, a Network Hardware error occurs.
Each error occurs for the following reasons.
Error
Reason
Alignment Errors
Broken packets for collision
FCS Errors
Broken packets for collision
Carrier Sense Errors
Cable disconnected, Cable defect, or Transceiver defect
Range is 0 to 100 percent. Default value is 50 percent.
Transmission Retry (%)
Specify the threshold of the percentage of collision and delay packets in total transmission packets per
monitoring cycle. Transmission Retry will occur when the server is under the high network load. Range is
10 to 50 percent. Default value is 35 percent.
Transmission Abort (%)
Specify the threshold of the percentage of packets disposed due to excess collisions errors, etc., in total
transmission packets per monitoring cycle. Transmission Abort will occur when the server is under the
high network load. Range is 10 to 50 percent. Default value is 35 percent.
[ok]
Settings are saved and this screen closes.
[cancel]
This screen closes without saving changes.