142 Appendix A. Supplementary Hardware Information
Use the appropriate SCSI cable to connect each host bus adapter to the storage enclosure.
Setting host bus adapter termination is done in the adapter BIOS utility during system boot.
To set RAID controller termination, refer to the vendor documentation. Figure A-3 shows
a configuration that uses two single-initiator SCSI buses.
Figure A-3. Single-initiator SCSI Bus Configuration
Figure A-4 shows the termination in a single-controller RAID array connected to two
single-initiator SCSI buses.
Figure A-4. Single-controller RAID Array Connected to Single-initiator SCSI Buses
Figure A-5 shows the termination in a dual-controller RAID array connected to two single-
initiator SCSI buses.