Red Hat NETSCAPE MANAGEMENT SYSTEM 4.5 Manuel d'utilisateur Page 256

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 286
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 255
Resource Management
256
www.vmware.com
The same procfs node can also be used to issue commands supported by the
nfshaper class. For example, you can dynamically adjust the bandwidth limits by
issuing a config command:
echo "config 128k 256k 20k"> \
/proc/vmware/filters/xmit/nfshaper.2.104
Note: This command should be entered on a single line. Do not type the backslash.
When a virtual machine is terminated, all attached network filters are automatically
removed and destroyed. To manually remove a shaper instance you can issue an
xmitpop command as described in Using Network Filters on page 253. Note that
root privileges are required to detach a filter.
echo "104" > /proc/vmware/filters/xmitpop
Vue de la page 255
1 2 ... 251 252 253 254 255 256 257 258 259 260 261 ... 285 286

Commentaires sur ces manuels

Pas de commentaire